Running Pipe Through Floor Joists
The hole cannot be larger than one third the depth of the joist so the maximum hole size for a 2 12 joist actual size 1 1 2 x 11 1 4 in is 3 3 4 in.
Running pipe through floor joists. Copper for copper and metal with metal only protection and prevention will stop the noise from happening. Rose sagady via email none. When you run your pipes through a joist you will have to be careful with your work. And use products that are compatible with the type of metal you are supporting.
Diameter plenty big enough for running cable. But they were run under the joists instead of through them as would be required by code for electrical wires. You can drill the holes anywhere along the length of the joist first photo. Step 4 cut the holes.
When it s undesirable for the sewer line to extend below the bottom of the floor joists the best option is to run the pipe parallel between two joists. Step 3 understand the joist slopes. The holes must follow a straight line across the floor and must ascend or descend so the pipe will be sloped 1 4 inch per foot. A pipe passing through a wooden item will also make noise so use caution and install a rubber sleeve even if you have to make one yourself with flat rubber gasket material.
If joists are 16 inches on center and pipes run across them at a right angle holes should differ in height by about 3 8 inch. It is never advisable to notch out or cut into floor joists or support beams as this may weaken the structural integrity of the building. For example instead of running a bathtub drain over floor joists the drain line can be dropped into the basement and connected to the main drain line beneath the joists. This is an engineering question and has to do with the structural loading of the floor above and the reduced load ratings on those joists.
Each joist must have a separate notch or hole and each. So the otherwise flat ceiling has an 18 foot long section where the drywall is an inch lower than the surrounding drywall. The lower section is about 8 wide to accomodate the two pipes. Or find a better way to run that pipe at 2 diameter that seems to be a venting pipe.
Editorial adviser mike guertin replies. The international building code irc has specific guidelines with illustrations for drilling and notching solid lumber floor joists. Engineered floor joists can be drilled only. You are going to need to add joists to accommodate the load of the second floor.
The holes will have to follow a straight line that goes across the floor and has to either go up or go down so the pipe has a slope. Running drainpipe through joists calls for meticulous work. The slope should be about 1 4 for each foot of pipe. Running drainpipes through floor joists is more complicated than running them parallel to the joists.